 * TEMPERATURE COMPENSATED ZENER REFERENCE DIODES * LEADLESS PACKAGE FOR SURFACE MOUNT * 12.8 VOLT NOMINAL ZENER VOLTAGE + 5% * LOW NOISE * METALLURGICALLY BONDED * DOUBLE PLUG CONSTRUCTION MAXIMUM RATINGS
Operating Temperature: -65C to +175C Storage Temperature: -65C to +175C DC Power Dissipation: 500mW @ +50C Power Derating: 4 mW / C above +50C
CDLL4896 thru CDLL4915A
REVERSE LEAKAGE CURRENT
lR = 15 A @ 25C & VR = 8Vdc ELECTRICAL CHARACTERISTICS @ 25C, unless otherwise specified.
CDI TYPE NUMBER (Note 3) mA CDLL4896 CDLL4896A CDLL4897 CDLL4897A CDLL4898 CDLL4898A CDLL4899 CDLL4899A CDLL4900 CDLL4900A CDLL4901 CDLL4901A CDLL4902 CDLL4902A CDLL4903 CDLL4903A CDLL4904 CDLL4904A CDLL4905 CDLL4905A CDLL4906 CDLL4906A CDLL4907 CDLL4907A CDLL4908 CDLL4908A CDLL4909 CDLL4909A CDLL4910 CDLL4910A CDLL4911 CDLL4911A CDLL4912 CDLL4912A CDLL4913 CDLL4913A CDLL4914 CDLL4914A CDLL4915 CDLL4915A 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 VOLTAGE TEMPERATURE STABILITY VZT (Note 2) mV 96 198 48 99 19 40 10 20 96 198 48 99 19 40 10 20 96 198 48 99 19 40 10 20 96 198 48 99 19 40 10 20 96 198 48 99 19 40 10 20 EFFECTIVE TEMPERATURE COEFFICIENT MAXIMUM DYNAMIC IMPEDANCE ZZT (Note 1) OHMS 400 400 400 400 400 400 400 400 200 200 200 200 200 200 200 200 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 50 25 25 25 25 25 25 25 25 MAXIMUM NOISE DENSITY ND
TEST CURRENT l ZT
TEMPERATURE RANGE
C +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100 +25 to +100 -55 to +100
%/C 0.01 0.01 0.005 0.005 0.002 0.002 0.001 0.001 0.01 0.01 0.005 0.005 0.002 0.002 0.001 0.001 0.01 0.01 0.005 0.005 0.002 0.002 0.001 0.001 0.01 0.01 0.005 0.005 0.002 0.002 0.001 0.001 0.01 0.01 0.005 0.005 0.002 0.002 0.001 0.001
V/
0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20
Hz
DIM D F G G1 S
MILLIMETERS INCHES MIN MAX MIN MAX 1.60 1.70 0.063 0.067 0.41 0.55 0.016 0.022 3.30 3.70 .130 .146 2.54 REF. .100 REF. 0.03 MIN. .001 MIN.
FIGURE 1
DESIGN DATA
CASE: DO-213AA, Hermetically sealed glass case. (MELF, SOD-80, LL34) LEAD FINISH: Tin / Lead POLARITY: Diode to be operated with the banded (cathode) end positive. MOUNTING POSITION: Any. MOUNTING SURFACE SELECTION: The Axial Coefficient of Expansion (COE) Of this Device is Approximately +6PPM/C. The COE of the Mounting Surface System Should Be Selected To Provide A Suitable Match With This Device.
NOTE 1 NOTE 2 NOTE 3
Zener impedance is derived by superimposing on lZT A 60Hz rms a.c. current equal to 10% of lZT. The maximum allowable change observed over the entire temperature range, per JEDEC standard No.5. Zener voltage range equals 12.8 volts + 5%.
22 COREY STREET, MELROSE, MASSACHUSETTS 02176 PHONE (781) 665-1071 FAX (781) 665-7379 WEBSITE: http://www.cdi-diodes.com E-mail: mail@cdi-diodes.com
CDLL4896
1000 500 ZENER IMPEDANCE ZZT (OHMS) 200 100 50 20 10 5 2 1
thru
CDLL4915A
2 4 6 8 10 12 OPERATING CURRENT lZT (mA)
FIGURE 2
ZENER IMPEDANCE VS. OPERATING CURRENT
CHANGE IN TEMPERATURE COEFFICIENT ( %/C)
CDLL4896 - CDLL4999
+.0015 +.0010 +.0005 0 -.0005 -.0010 -.0015 .2 .4 .6 .8 OPERATING CURRENT lZT (mA)
CDLL4900 - CDLL4903
CDLL4904 - CDLL4907
0.5 1.0 1.5 2.0 OPERATING CURRENT lZT (mA)
1.0 2.0 3.0 4.0 OPERATING CURRENT lZT (mA)
CDLL4908 - CDLL4911
CHANGE IN TEMPERATURE COEFFICIENT ( %/C) +.0015 +.0010 +.0005 0 -.0005 -.0010 -.0015 2 3 4 5 6 OPERATING CURRENT lZT (mA)
CDLL4912 - CDLL4915
6 7 8 9 OPERATING CURRENT lZT (mA)
FIGURE 3
TYPICAL CHANGE OF TEMPERATURE COEFFICIENT WITH CHANGE IN OPERATING CURRENT


▲Up To Search▲   

 
Price & Availability of CDLL4901A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X